Product Details:
|
| Life Cycle: | 10000 Cycles | Voltage & Current: | 250V 2A |
|---|---|---|---|
| Contact Type: | Normally Closed Or Normally Open | Switch Type: | Auto Reset Or Manual Reset |
| Temperature Range: | 30-150℃ | Case: | Plastic |
| Highlight: | BW-DCM Temperature Controlled Switch,BW-DCP Thermal Fuse bimetallic thermostat,Auto Reset Thermal Fuse bimetallic thermostat |
||
BH series thermostat / Miniature thermal protector / Rechargeable battery thermostat
Visit our website for more information: www.thermostat-cn.com
BW & BH series protectors offer reliable protection against over-current and over-temperature conditions. These sealed units feature small internal resistance, no noise operation, and automatic reset functionality.
When current passes through the temperature and current-sensitive bimetal, the bimetal's status changes in response to over-temperature or over-current conditions, either cutting off or switching on the circuit. BH series protectors provide enhanced safety compared to standard protectors, as they eliminate temperature effect lag during sudden high-current conditions.
| Parameter | Specification |
|---|---|
| Electrical Rating | DC-12V max 12A; DC-24V max 10A; AC-125V max 8A; AC-250V max 16A |
| Open Temperature | (30~150)±5°C; 5°C steps |
| Reset Temperature | 2/3 of action temperature with ±15°C tolerance. Custom reset temperatures available per customer requirements. |
| Life Times | 10,000 cycles |
| Size | L15mm × W7.1mm × H3.8mm |
| Lead Wire | #22 3266, end half tripping, 70mm length (custom lengths available) |
| UL File No | E487478 |
| CQC Certificate No | CQC16002142880 |
| TUV Certificate No | B160592241002 |
| Model | Case | Length (mm) | Width (mm) | Height (mm) | Voltage & Current | Lead Wire |
|---|---|---|---|---|---|---|
| H20 | Plastic | 18.5 | 8 | 4 | DC-12V max 12A; DC-24V max 10A; AC-125V max 8A; AC-250V max 10A | #20 3135, end 5mm half tripping, 70mm length (custom available) |
| H21 | Metal | 18.5 | 7.3 | 3.8 | - | - |
| H21 | Metal | 20 | 8 | 4 | AC250V 20A | #16 3135 |
| BH-A1D | Metal | 15 | 6.6 | 3.2 | DC-12V max 12A; DC-24V max 10A; AC-125V max 8A; AC-250V | #20 3135, #22 3266, #22 3135, end 5mm half tripping, 70mm length (custom available) |
| BH-B2D | Plastic | 15 | 7.1 | 3.8 | - | - |
| BH-TB02B-B8D | Plastic | 15 | 5.2 | 2.4 | DC-12V max 4A; DC-24V max 3A; AC-125V max 3A; AC-250V max 2A | 3266-AWG24#, 3135-AWG24# or nickel strip, 70mm length (custom available) |
BH series thermal protectors serve as effective and reliable security protection and alarm devices, widely used in various applications including:
These protectors prevent damage from over-current and over-heating caused by abnormal operating conditions. Enforced types capable of withstanding pressures up to 3.5MPa are suitable for built-in installation in plastic coated motors.
| Code | Temperature | Code | Temperature |
|---|---|---|---|
| 30 | 30℃ | 100 | 100℃ |
| 35 | 35℃ | 105 | 105℃ |
| 40 | 40℃ | 110 | 110℃ |
| 45 | 45℃ | 115 | 115℃ |
| 50 | 50℃ | 120 | 120℃ |
| 55 | 55℃ | 125 | 125℃ |
| 60 | 60℃ | 130 | 130℃ |
| 70 | 70℃ | 135 | 135℃ |
| 75 | 75℃ | 140 | 140℃ |
| 80 | 80℃ | 145 | 145℃ |
| 85 | 85℃ | 150 | 150℃ |
| 90 | 90℃ |
H20 and H21 series universal and enhanced protectors feature large metal casings and are composed of thermal conductive metal casing, bimetallic parts welded with silver alloy contact points, conductive brackets, insulation fixation stands, fixed contact strips, and heat resistance cables.
During abnormal operation, as environmental temperature increases to the set value, the bimetallic components perform quick action, opening the contact points and disconnecting the circuit. When the device cools to safe operating temperature, the contact points automatically close and normal operation resumes.
| Parameter | Specification |
|---|---|
| Electrical Rating | DC-12V max 12A; DC-24V max 10A; AC-125V max 8A; AC-250V max 16A |
| Open Temperature | (30~150)±5°C; 5°C steps |
| Reset Temperature | 2/3 of action temperature with ±15°C tolerance. Custom reset temperatures available per customer requirements. |
| Life Times | 10,000 cycles |
| Contact Closure Resistance | ≤50mΩ |
| Insulation Resistance | ≥100mΩ |
| Electric Strength | AC1500V/1min free from phenomena of breakdown and flashover |
| UL File No | E487478 |
| CQC Certificate No | CQC16002142880 |
| TUV Certificate No | B160592241002 |
H20 and H21 series protectors are suitable for various applications including:
Contact Person: Cherry Lee
Tel: +86-13431163393
Fax: 86-769-82657011